Temperature-controlled refrigerated storage and low-temperature pharmaceutical studies from 2 to 14 °C. Select the chamber size and confirm sample storage requirements.
Technical Information
| Model | PT-CST-001 |
|---|
| Temperature range (°C) | 2-14 |
|---|
| Temperature fluctuation (°C) | ±0.5 |
|---|
| Temperature deviation (°C) | ±2 |
|---|
| Power supply | 220 V / 50 Hz |
|---|
| Operating ambient conditions | 5-35 °C; ≤85% RH |
|---|
Configuration A
| Compressor sets | 2 |
|---|
| Installed power (W) | 1000 |
|---|
| Internal dimensions (mm) | 440×500×570 |
|---|
| External dimensions (mm) | 950×690×1330 |
|---|
| Packed dimensions (mm) | 1040×800×1510 |
|---|
| Net mass (kg) | 160 |
|---|
| Shelves | 2 |
|---|
Configuration B
| Compressor sets | 2 |
|---|
| Installed power (W) | 1000 |
|---|
| Internal dimensions (mm) | 440×500×920 |
|---|
| External dimensions (mm) | 950×690×1670 |
|---|
| Packed dimensions (mm) | 1040×800×1870 |
|---|
| Net mass (kg) | 200 |
|---|
| Shelves | 4 |
|---|
Configuration C
| Compressor sets | 2 |
|---|
| Installed power (W) | 2000 |
|---|
| Internal dimensions (mm) | 600×600×1000 |
|---|
| External dimensions (mm) | 1110×790×1760 |
|---|
| Packed dimensions (mm) | 1200×880×1950 |
|---|
| Net mass (kg) | 250 |
|---|
| Shelves | 4 |
|---|
Configuration D
| Compressor sets | 2 |
|---|
| Installed power (W) | 2000 |
|---|
| Internal dimensions (mm) | 600×800×1000 |
|---|
| External dimensions (mm) | 1110×990×1760 |
|---|
| Packed dimensions (mm) | 1200×1090×1950 |
|---|
| Net mass (kg) | 270 |
|---|
| Shelves | 4 |
|---|
Configuration E
| Compressor sets | 2 |
|---|
| Installed power (W) | 3000 |
|---|
| Internal dimensions (mm) | 1000×1000×1000 |
|---|
| External dimensions (mm) | 1510×1190×1760 |
|---|
| Packed dimensions (mm) | 1600×1290×1950 |
|---|
| Net mass (kg) | 380 |
|---|
| Shelves | 4 |
|---|
Performance values are specified for the selected configuration. Do not combine temperature or humidity limits from different configurations. Supply is listed as 220 V / 50 Hz; other electrical requirements need confirmation.
Equipment & Construction
Forced-air circulation, digital temperature control, a stainless-steel interior and overtemperature protection. The listed configuration determines chamber dimensions and shelf quantity.
Configuration Options
Confirm recording, monitoring, qualification documents and any additional accessories in the quotation. These are not a blanket certification or a promise of standard supply.
Ordering Information
Specify the series model, configuration letter, sample load, setpoints, installation space and destination power requirements. All dimensions are depth × width × height. Confirm the final configuration and applicable test protocol before ordering.