Controlled-temperature incubation for fungal culture, with ventilation openings and UV lamps. Select the temperature range and chamber dimensions for your protocol.
Technical Information
| Model | PT-INC-109 |
|---|
| Temperature fluctuation (°C) | ±1 |
|---|
| Temperature deviation (°C) | ±2 |
|---|
| Power supply | 220 V / 50 Hz |
|---|
| Operating ambient conditions | 5-35 °C; ≤85% RH |
|---|
Configuration A
| Temperature range (°C) | 4-50 |
|---|
| Installed power (W) | 900 |
|---|
| Internal dimensions (mm) | 440×500×570 |
|---|
| External dimensions (mm) | 720×650×1210 |
|---|
| Packed dimensions (mm) | 800×730×1400 |
|---|
| Net mass (kg) | 105 |
|---|
| Shelves | 2 |
|---|
Configuration B
| Temperature range (°C) | 4-50 |
|---|
| Installed power (W) | 900 |
|---|
| Internal dimensions (mm) | 440×500×920 |
|---|
| External dimensions (mm) | 720×650×1560 |
|---|
| Packed dimensions (mm) | 800×730×1760 |
|---|
| Net mass (kg) | 120 |
|---|
| Shelves | 4 |
|---|
Configuration C
| Temperature range (°C) | 15-50 |
|---|
| Installed power (W) | 950 |
|---|
| Internal dimensions (mm) | 600×600×1000 |
|---|
| External dimensions (mm) | 1110×790×1760 |
|---|
| Packed dimensions (mm) | 1200×880×1950 |
|---|
| Net mass (kg) | 210 |
|---|
| Shelves | 4 |
|---|
Configuration D
| Temperature range (°C) | 15-50 |
|---|
| Installed power (W) | 950 |
|---|
| Internal dimensions (mm) | 600×800×1000 |
|---|
| External dimensions (mm) | 1110×990×1760 |
|---|
| Packed dimensions (mm) | 1200×1090×1950 |
|---|
| Net mass (kg) | 250 |
|---|
| Shelves | 4 |
|---|
Configuration E
| Temperature range (°C) | 15-50 |
|---|
| Installed power (W) | 1900 |
|---|
| Internal dimensions (mm) | 1000×1000×1000 |
|---|
| External dimensions (mm) | 1510×1190×1760 |
|---|
| Packed dimensions (mm) | 1600×1290×1950 |
|---|
| Net mass (kg) | 370 |
|---|
| Shelves | 4 |
|---|
Performance values are specified for the selected configuration. Do not combine temperature or humidity limits from different configurations. Supply is listed as 220 V / 50 Hz; other electrical requirements need confirmation.
Equipment & Construction
Forced-air circulation, digital temperature control, a stainless-steel interior and overtemperature protection. The listed configuration determines chamber dimensions and shelf quantity. Ventilation openings and UV lamps are included; UV operation must follow the laboratory protocol.
Configuration Options
Confirm recording, monitoring, qualification documents and any additional accessories in the quotation. These are not a blanket certification or a promise of standard supply.
Ordering Information
Specify the series model, configuration letter, sample load, setpoints, installation space and destination power requirements. All dimensions are depth × width × height. Confirm the final configuration and applicable test protocol before ordering.